2.2 kW Variable Frequency Drive — for Pumps, Fans, and Conveyors

A 2.2 kW variable frequency drive is one of the most popular sizes for small and medium industrial mechanisms. Models are available for single-phase 220V (1ph input, 3ph output) and three-phase 380V supply. Used for speed control of pumps, fans, conveyors, mixers, and woodworking machines.

How to Choose a 2.2 kW VFD: Single-Phase or Three-Phase

The choice depends on the available power supply and motor type. Single-phase models (220V input) suit domestic and small production sites. Three-phase (380V) models are for industrial applications with full protection features.

ModelSeriesSupplyApplication
Veichi AC10-T3-2R2G-BAC103ph 380VConveyors, machine tools
Veichi AC310-T3-2R2G-BAC3103ph 380VPumps, fans (built-in PID)
Veichi AC10-T/S2-2R2G-B-VCAC101ph 220VDomestic pumps, small machines
Delta VFD022E43AVFD-E3ph 380VUniversal industrial mechanisms
INVT GD20-2R2G-4GD203ph 380VConveyors, extruders

Common Mistakes When Selecting a 2.2 kW VFD

  • Selecting by power instead of current — a 2.2 kW motor from different manufacturers may draw 5 to 10A. Always match the VFD to the motor rated current.
  • Single-phase VFD on a three-phase supply — single-phase models (220V input) do not work with 380V. Check the supply type.
  • No headroom for heavy-duty starts — for conveyors, crushers, and high-inertia loads, choose one size up (3 kW).
  • Scalar mode for precision mechanisms — for machines requiring speed accuracy, choose a vector VFD, not scalar.

When You Need Power Headroom

MechanismRecommended VFD PowerReason
Pump, fan2.2 kW (1:1)Easy start, constant load
Unloaded conveyor2.2 kW (1:1)Standard starting torque
Loaded conveyor3 kW (+30%)Increased starting torque
Crusher, mixer3 kW5.5 kWHeavy start, load inertia
Machine with reverse3 kW (+30%)Frequent braking and reverse

2.2 kW VFD Manufacturers

Brands ranked by sales volume over the last 12 months:

  • Veichi — AC10, AC310, AC01 series. Sales leader: 140+ units. Optimal price-to-performance ratio.
  • Delta Electronics — VFD-E, VFD-EL series. Proven industrial reliability, extensive service network.
  • INVT — GD20 series. Budget segment with full protection set.
  • Mitsubishi Electric — FR-D series. Premium class for precision applications.

Related Categories by Power

  • VFD 3 kW — next size up for power headroom
  • VFD 5.5 kW — for medium industrial mechanisms
  • VFD 7.5 kW — for heavy-duty pumping stations

Warranty and Delivery

All 2.2 kW VFDs come with official manufacturer warranty of 18 to 24 months. Delivery across Ukraine — Kyiv, Kharkiv, Odesa, Dnipro, Lviv, and other cities.

Frequently Asked Questions

Which 2.2 kW VFD should I choose?

For pumps and fans, a scalar VFD works (Delta VFD-EL, Schneider ATV12). For machines and conveyors, choose vector control (Danfoss FC51, ABB ACS150). For single-phase 220V supply, select a model with single-phase input.

How to wire a 2.2 kW VFD correctly?

Wiring diagram: connect 220V or 380V mains to terminals L1/L2/L3 (input), connect the motor to terminals U/V/W (output). Always install a circuit breaker at the input and proper grounding. Cable between VFD and motor should not exceed 50 m without an output choke.

Can I connect a 2.2 kW VFD to 220V?

Yes, models with single-phase 220V input and three-phase output are available. For example, Delta VFD-EL, Schneider ATV12, INVT GD10 convert single-phase 220V to 3 phases for a 2.2 kW motor.

What motor protection does a VFD provide?

A VFD protects the motor from current overload, overheating (PTC/NTC sensor), short circuit, phase loss, and overvoltage. Built-in features include: inrush current limiting, soft start/stop, auto-restart after fault.

When do I need a power reserve — should I choose 3 kW instead of 2.2 kW?

A power reserve is needed for heavy-duty starts (compressor, loaded conveyor), frequent start-stop cycles, high ambient temperature (above +40°C), or long motor cables (over 30 m). In these cases, we recommend choosing a 3 kW VFD.