VFDs for generator-powered motor starting

When your motor is powered from a generator, a properly selected VFD reduces inrush current and improves startup stability. This is critical for pumps, fans, compressors, and process equipment sensitive to voltage dips.

Related collections: for pumps, for fans, for motors.

How to choose a VFD for operation from a generator

Use a generator power margin of at least 25-35% above drive nominal power, and 40-50% for hard-start applications. Check input voltage/phase compatibility, undervoltage protection limits, and acceleration ramp settings.

Model Brand Power Input Typical use
AC10-T3-1R5G-B Veichi 1.5 kW 3x380 V Pumps, fans, general industrial
VFD055E43A Delta Electronics 5.5 kW 3x380 V Variable load operation
GD20-004G-4 INVT 4 kW 3x380 V Industrial automation
132F0026 Danfoss 0.75 kW 3x380 V Energy-efficient systems
FR-D740-036SC-EC Mitsubishi Electric 1.5 kW 3x380 V Reliable startup and protection

Popular brands for generator startup tasks

Based on 12-month sales data: Veichi, Delta Electronics, INVT, Danfoss, Mitsubishi Electric.

Useful preset pages: single-phase 220V, three-phase 380V, vector control drives.

Filter by key parameters

Quick filters: 0.75 kW, 1.5 kW, 2.2 kW, 1x220 V, 3x380 V.

FAQ

What generator margin is recommended for a VFD?
Typically 25-35% above drive nominal power, and up to 40-50% for hard-start loads.

Can a VFD run with fluctuating generator voltage?
Yes, if protection thresholds and acceleration ramps are configured correctly.

V/F or vector control for generator supply?
V/F is often enough for pumps and fans; vector control is preferred for demanding torque conditions.

Why does the generator drop during startup?
Most cases are caused by insufficient generator reserve or too aggressive acceleration settings.

Read more setup guidance.

Warranty, support, payment and delivery

We help with model selection, generator compatibility checks, and commissioning support. Nationwide delivery across Ukraine with VAT invoicing available.

Frequently Asked Questions

How much generator reserve is needed for a VFD?

Use 25-35% reserve for normal loads and up to 40-50% for hard-start conditions.

Can I start a pump via VFD from a generator?

Yes. Set proper acceleration time and voltage/current protection thresholds.

Which mode is better with generator supply: V/F or vector?

V/F works for many pump/fan tasks; vector mode is better for demanding torque control.

Why does generator voltage dip at startup?

Usually due to insufficient generator margin or overly aggressive startup settings.