Skip to content
Selection by parameters
Main Power, kW
Hybrid Power (AC/DC-Solar)
Remote Control

VFDs 15 kW

Found 260 products
15 ×
Скинути фільтри
B2B Сервіс

15 kW VFD: where we ship it and when 18.5 kW makes more sense

The 15 kW size in our warehouse is the next step up from 11 kW. Rated current 32-33 A on three-phase 380 V. There are no single-phase options at this power: input current is too high for a 220 V household line. Typical customer this year: a pumping station with a centrifugal field-irrigation pump, an air compressor in a wood shop, or the drive motor of a 30 m belt conveyor. Sales leader over 12 months: Veichi AC10-T3-015G-B (14 units sold), scalar control.

If you have a pump or fan with frequent starts, or you need PID for pressure control, we ship Veichi AC310-T3-015G/018P-B (8 units). The two-number name is not random. In G mode (Heavy Duty) it is a 15 kW drive for heavy starts at 150% / 60 s; in P mode (Pump/Fan) the same unit handles 18.5 kW of light load. So you pay for 15 kW yet on a pump you get 18.5 kW. Ask whether your start is light: then P mode is the right pick. Schneider Altivar 610 ATV610D15N4 is also in our stock, ordered less often (one sale per year). Customers take it when they need a European brand for tender paperwork.

What we ask before ordering: start type and input wiring

First question. What you are spinning. Pump, fan: light start, AC310 in P mode or AC10 with current headroom. Screw, crusher, press: heavy start, G mode only (AC310 G or AC10), and we check whether you will need a braking resistor. Second question. What breaker is on the 380 V feed? At 15 kW the inrush current can reach 60-70 A, so the breaker should be at least 40 A type D or 50 A type C. A 32 A breaker will trip on start-up.

Third question. Do you need RS-485 / Modbus for SCADA? AC10 or AC310 has Modbus out of the box. The budget INVT GD20-015G-4 also has it, with fewer diagnostic registers. At 15 kW we always mount the unit in a cabinet with ventilation or air conditioning; basic IP20 of the stock models does not allow open mounting in a dusty workshop. Warranty: Veichi 24 months, Schneider 24 months. Delivery from our Kyiv warehouse takes 1-3 days. The unit weighs around 8-10 kg, we ship by Nova Poshta.

Comparison of 15 kW VFDs

ModelSupplyCurrentPrice, UAH
Simphoenix DX1003x38033 A23,334
Veichi AC103x38032 A27,362
INVT GD203x38032 A27,499
Veichi AC3103x38032 A33,712

How to choose a 15 kW VFD

Consider: supply type (single-phase 220V or three-phase 380V), control type (scalar or vector), application (pumps, fans, motors).

Other power ratings

2.2 kW · 3 kW · 5.5 kW · 7.5 kW · 11 kW · 22 kW

Warranty and delivery

24-month warranty. Delivery across Ukraine via Nova Poshta. Technical support for wiring and parameter configuration.

Frequently Asked Questions

Which motor is a 15 kW VFD selected for?

A 15 kW VFD is selected for a three-phase electric motor with a rated power of 15 kW when the motor current does not exceed the drive rated current. Before ordering, check the motor nameplate: power, voltage, current, and wiring diagram.

What input voltage is required for a 15 kW VFD?

The input voltage depends on the site supply and the motor. For a single-phase 220 V supply, choose a 220 V input model if it is available for this power. Industrial motors usually require a 3-phase 380 V VFD.

Do I need extra power reserve for a 15 kW VFD?

For pumps and fans, selecting by the motor rated power and current is often enough. For heavy starts, conveyors, compressors, mixers, or frequent acceleration cycles, allow extra current reserve or move to the next power size.

Where are 15 kW VFDs used?

15 kW VFDs are used to control the speed of pumps, fans, conveyors, machines, and other equipment with asynchronous motors. The exact application depends on load torque, duty cycle, and installation conditions.

How can I quickly choose the right model?

Send a motor nameplate photo or provide the power, voltage, rated current, number of phases, and load type. A Chastotnik.ua manager will select a compatible VFD, check availability, and advise on basic startup parameters.