Siemens VFDs: when SINAMICS, when a simpler brand fits

Customers buy Siemens SINAMICS from us when they are already standardized on the German lineup (S7-1200/1500 PLCs, ProfiNet panels) or when they sell into the EU where SIL 2 / PL d STO is required on the declaration. Our typical buyer this year: a machine builder shipping serial equipment to Germany or Poland, a food line with functional safety requirements, a water utility standardized on Siemens. Outside those scenarios we honestly point customers at Delta, INVT, or Schneider ATV. Same job for 30-50% less.

The catalog carries 182 Siemens models across 9 series, 0.1 to 900 kW. SINAMICS V20 is the workhorse 0.1-22 kW for pump, fan, conveyor jobs. Minimum parameters, runs in 15 minutes. SINAMICS G120 is modular (CU + PM), vector control, STO, programmable DCC logic right inside the drive. SINAMICS G110 is a 220 V single-phase compact up to 3 kW. MicroMaster 420/430/440 is the previous generation, still available from our stock, with a strong price-to-feature ratio.

What we ask before you order Siemens

First: the job and the surrounding system. If Siemens PLCs and ProfiNet are already there, G120 is the default with no debate, because S7 integration takes us an hour. If it is just a motor-pump with no PLC at all, V20 is cheaper and simpler. Second: power and supply. Single-phase 220 V up to 3 kW – G110 or V20. Three-phase 380 V – the full V20/G120/MicroMaster lineup, just pick the load class (LO for pump-fan, HO for heavy starts with 150% overload).

Third: safety. STO (Safe Torque Off) is not in V20, only G120 from CU240 up. If the project needs SIL 2 / PL d per EN 62061, it has to be G120 with the safety module. We ship popular 1.5 / 3 / 5.5 / 11 / 22 kW from our Kyiv warehouse in 1 day. Other series come on factory order in 2-4 weeks. Siemens factory warranty is 12 months from commissioning, extension to 24 months is optional via service. We do series selection and start-up parameters free. Our typical customer gets a parameter file for their specific job along with the drive.

Siemens Variable Frequency Drive Series

Series Power Range Supply Voltage Models Typical Application
SINAMICS V20 0.1 – 22 kW 1×220 V / 3×380 V 48 Pumps, fans, conveyors — quick commissioning, minimal parameterisation
SINAMICS G120 0.4 – 250 kW 1×220 V / 3×380 V / 3×500 V 313 Modular CU + PM design. Vector control, integrated PLC, Safe Torque Off (STO)
SINAMICS G110 0.1 – 3 kW 1×220 V 56 Compact single-phase drives for small pumps and conveyors
MicroMaster 420 0.2 – 11 kW 1×220 V / 3×380 V 40 General-purpose motor control, easy integration with existing automation
MicroMaster 430 7.5 – 250 kW 3×380 V 27 High-power pumps and fans with built-in PID controller
MicroMaster 440 0.2 – 200 kW 1×220 V / 3×380 V 81 Hoisting equipment, textiles, complex vector control applications

Most Popular Models In Stock

Siemens VFD models most frequently chosen by our customers:

Model Series Power Supply Current (A)
Siemens 6SL3210-5BE21-5UV0 SINAMICS V20 1.5 kW 3×380 V 4.1
Siemens 6SL3210-5BE23-0UV0 SINAMICS V20 3.0 kW 3×380 V 7.3
Siemens 6SL3210-1NE14-1UL0 SINAMICS G120 1.5 kW 3×380 V 4.1

Why Choose Siemens Frequency Converters

  • Wide power range — from 0.1 kW (SINAMICS G110) to 900 kW (SINAMICS G150): solutions for every industrial scale.
  • Safety: STO (Safe Torque Off) — hardware safety function in the G120 series, certified to SIL 2 / PL d.
  • Modbus RTU / PROFIBUS / PROFINET — broad communication options for SCADA and Siemens S7-1200/S7-1500 PLC integration.
  • Embedded PLC (DCC) — the G120 supports Drive Control Chart programming for simple automation tasks without an external controller.
  • Energy savings — the P/N (pump and fan) mode reduces energy consumption by up to 30 % versus direct motor starting.

How to Select a Siemens VFD

  • Motor power (kW) — the drive rating should match or exceed the motor nameplate power by 10–20 % under heavy starting conditions.
  • Supply voltage — for a single-phase 220 V network choose SINAMICS V20 or MicroMaster 420/440; for three-phase 380 V the full lineup is available.
  • Load type — for pumps and fans choose V20 or MicroMaster 430; for hoisting and textile machinery choose MicroMaster 440 or G120 with vector control.
  • Communication interface — if PLC integration is required, select the G120 with an optional PROFIBUS or PROFINET module.

Related Categories

Warranty and Support

All Siemens frequency converters at chastotnik.ua are supplied with the manufacturer's official warranty. Our engineers provide free technical consultation for series selection and parameter configuration. Delivery across Ukraine via Nova Poshta — same-day dispatch for in-stock items.

Frequently Asked Questions

Which Siemens VFD series are available in the catalogue?

The catalogue includes SINAMICS V20 from 0.12 to 15 kW for pumps, fans and standard machinery; modular Sinamics G120 from 0.55 to 132 kW featuring PM240-2 power modules paired with CU240E-2 or CU250S-2 control units (Profinet, Profibus, STO safety functions); and legacy MicroMaster 420/440 units for industrial retrofits.

How do you configure SINAMICS V20 without a PC?

The V20 is commissioned directly from its built-in BOP operator panel using connection macros Cn001–Cn011 and application macros AP001–AP021. This lets you enter motor nameplate parameters (P0304–P0311), start commands and frequency references in 3 to 5 minutes without dedicated software.

What is the difference between modular G120 and compact V20?

Sinamics G120 separates the power stage (PM240-2) from the control unit (CU240E-2 DP/PN). This allows fieldbus selection (Profinet/Profibus), native TIA Portal engineering, closed-loop encoder vector control and SIL 3 / PLe STO safety. In contrast, V20 is a compact monoblock drive with integrated Modbus RTU.

Can Siemens drives handle heavy-duty starting loads?

Yes. For heavy-duty applications such as crushers, conveyors and extruders, G120 drives support Heavy Duty rating (150% overload for 60 s or 200% for 3 s). On the V20 series with high breakaway torque, we recommend sizing up one frame size above the motor rating.

What are the lead times and warranty terms for Siemens drives?

Popular SINAMICS V20 ratings up to 15 kW and standard G120 modules ship from local Ukrainian stock in 1-3 working days. High-power industrial modules arrive on order within 5 to 15 days. Official manufacturer warranty is 24 months.