1.5 kW VFD: when this rating is the right choice

A 1.5 kW VFD is selected for a 1.5 kW electric motor when the motor rated current does not exceed the drive current rating. This is a common size for small pumps, fans, conveyors, mixers, packaging equipment, and light machine drives.

Before selecting a drive, check not only the power but also the motor voltage, number of phases, duty cycle, and load type. A standard 1.5 kW VFD is usually enough for a simple pump or fan, while heavy starting loads may require extra current reserve.

220 V or 380 V

If only a single-phase supply is available, choose a 220 V input model for a compatible three-phase 220 V motor. For an industrial supply, choose a 3-phase 380 V VFD. A voltage mismatch is one of the most common selection mistakes.

Where 1.5 kW VFDs are used

  • Pumps — soft start, pressure control, sensor input, and PID control.
  • Fans — capacity control and energy savings.
  • Conveyors — smooth acceleration, gentle stopping, and line speed adjustment.
  • Mixers and small mechanisms — stable speed and motor protection.

How to order without a mismatch

Send a motor nameplate photo or provide the power, voltage, rated current, number of phases, and load type. We will select a compatible 1.5 kW VFD, check availability, and advise on the basic startup settings.

Frequently Asked Questions

Which motor is a 1.5 kW VFD selected for?

A 1.5 kW VFD is selected for a three-phase electric motor with a rated power of 1.5 kW when the motor current does not exceed the drive rated current. Before ordering, check the motor nameplate: power, voltage, current, and wiring diagram.

What input voltage is required for a 1.5 kW VFD?

The input voltage depends on the site supply and the motor. For a single-phase 220 V supply, choose a 220 V input model if it is available for this power. Industrial motors usually require a 3-phase 380 V VFD.

Do I need extra power reserve for a 1.5 kW VFD?

For pumps and fans, selecting by the motor rated power and current is often enough. For heavy starts, conveyors, compressors, mixers, or frequent acceleration cycles, allow extra current reserve or move to the next power size.

Where are 1.5 kW VFDs used?

1.5 kW VFDs are used to control the speed of pumps, fans, conveyors, machines, and other equipment with asynchronous motors. The exact application depends on load torque, duty cycle, and installation conditions.

How can I quickly choose the right model?

Send a motor nameplate photo or provide the power, voltage, rated current, number of phases, and load type. A Chastotnik.ua manager will select a compatible VFD, check availability, and advise on basic startup parameters.