Skip to content
Selection by parameters
Main Power, kW
Supply input, V
Hybrid Power (AC/DC-Solar)
Remote Control

VFDs 22 kW

Found 225 products
22 ×
Скинути фільтри
B2B Сервіс

22 kW VFD: G-mode or P-mode, what 22/30 in the model name means

The 22 kW size in our warehouse is taken by customers moving from soft starters or auto-transformers to true variable speed without paying for the next power tier. Rated current 45-46 A on three-phase 380 V. There are no single-phase options at this power. Typical customer this year: a pumping station with two 11 kW centrifugal pumps in parallel, the main belt-conveyor drive at a quarry, or a compressor in a large workshop. Sales leader: Veichi AC310-T3-022G/030P-B (10 units in 12 months), vector with PID. The double name is intentional. In G mode it is a 22 kW drive for heavy starts; in P mode the same unit handles 30 kW of light load (pumps, fans).

The cheaper scalar option is Veichi AC10-T3-022G-B (8 units). Customers take it for open-loop motors where stable frequency is enough, for example dosing-pump drives. INVT GD200A-022G/030P-4 in our stock is the alternative to AC310 in the same G/P format. The budget pick is Simphoenix DX100-4T0220Q, ordered less often, with all the basic overload and phase-loss protections.

What we ask before ordering: G or P, cabinet, braking

First question. Is your load G-duty (Heavy Duty 150% / 60 s) or P-duty (Pump/Fan 110% / 60 s)? Crusher, screw, press, extruder: that is G. Pump, fan, centrifuge with slow ramp-up: that is P. On AC310-T3-022G/030P it is the same hardware, you just switch a menu parameter before start-up. On AC10 you pay for a fixed class, namely G. Second question. What cable arrives at the install point? At 45 A, copper 16 mm² is the minimum; at 70 A inrush, anything below a 63 A type-D breaker will trip on start.

Third question. Will you need a braking resistor? On 22 kW motors with high-inertia shafts, stopping without a resistor means an overvoltage trip in half a second. The AC10 or AC310 still has the braking module built in at this power (above 22 kW it becomes an external unit). We size the resistor by load inertia: ask us, we work it out together from the datasheet. On a wall without a cabinet, 22 kW does not survive: minimum IP54 cabinet with forced ventilation. Warranty: Veichi 24 months, INVT 24 months. Delivery from our Kyiv warehouse takes 1-3 days, the unit weighs around 12-14 kg, shipped via Nova Poshta.

Comparison of 22 kW VFDs

ModelSupplyCurrentPrice, UAH
Simphoenix DX1003x38045 A31,763
Veichi AC103x38045 A39,802
Lenze ESMD3x38046 A40,287
INVT GD200A3x38045 A43,999

How to choose a 22 kW VFD

Consider: supply type (single-phase 220V or three-phase 380V), control type (scalar or vector), application (pumps, fans, motors).

Other power ratings

2.2 kW · 3 kW · 5.5 kW · 7.5 kW · 11 kW · 15 kW

Warranty and delivery

24-month warranty. Delivery across Ukraine via Nova Poshta. Technical support for wiring and parameter configuration.

Frequently Asked Questions

Which motor is a 22 kW VFD selected for?

A 22 kW VFD is selected for a three-phase electric motor with a rated power of 22 kW when the motor current does not exceed the drive rated current. Before ordering, check the motor nameplate: power, voltage, current, and wiring diagram.

What input voltage is required for a 22 kW VFD?

The input voltage depends on the site supply and the motor. For a single-phase 220 V supply, choose a 220 V input model if it is available for this power. Industrial motors usually require a 3-phase 380 V VFD.

Do I need extra power reserve for a 22 kW VFD?

For pumps and fans, selecting by the motor rated power and current is often enough. For heavy starts, conveyors, compressors, mixers, or frequent acceleration cycles, allow extra current reserve or move to the next power size.

Where are 22 kW VFDs used?

22 kW VFDs are used to control the speed of pumps, fans, conveyors, machines, and other equipment with asynchronous motors. The exact application depends on load torque, duty cycle, and installation conditions.

How can I quickly choose the right model?