AL2-14MR-D Alpha XL PLC base module for DC 24 V supply; 8 inputs DC 24 V; 6 relay outputs
Є в наявності
sku: AL2-14MR-D
Є в наявності
Ціна за запитом
brand: Mitsubishi Electric
Series: Alpha-2
module type: PLC
supply_voltage:
output_type:
Interface: No
Number of inputs: 8
Relay outputs:
USB port:
Number of digital outputs: 6
high_speed_outputs:
Delivery and payment methods
By Nova Poshta to a branch or courier to the address
Bank transfer payment
Service and Warranty
- 24-month Warranty
- Product return within 14 days
- Official Service Center
Technical support
- Help with setup and selection
- Зацікавив товар?
Наш продавець проконсультує Вас.
- Characteristics
- Documentation
- Reviews (0)
| brand | Mitsubishi Electric |
| Series | Alpha-2 |
| module type | PLC |
| sku | AL2-14MR-D |
| supply_voltage_V | 24DC |
| Number of inputs | 8 |
| Number of digital inputs | 8 |
| Input voltage | 24DC |
| Type of discrete input signals | PNP #NPN |
| Number of analog inputs | 8 |
| Type of analog inputs | No |
| Number of high frequency inputs | No |
| Input frequency | нет kHz |
| Number of outputs | 6 |
| Number of digital outputs | 6 |
| Type of digital outputs | релейні |
| Number of analog outputs | No |
| Type of analog outputs | No |
| Maximum voltage/current output common per point | AC 250В # DC 30В # 8 А |
| Number of ports | No |
Documents by language
Ukrainian / English / Russian
Chastotnik.ua
Practical setup guides
Chastotnik.ua materials for wiring and setup. These are not official manufacturer documents.
Guide
Replacing a European VFD with Veichi: NPN/PNP, PLC jumper, COM vs GND
The most common scenario when replacing a European drive (Schneider Altivar, Siemens, LS, Danfoss) with Veichi looks like this: the power section is w...
Go to
Guide
COM or GND: why the buttons do not work on a Veichi VFD
A typical picture after installation: the Veichi VFD starts from the keypad, the parameters are entered, but the external Start/Stop buttons produce n...
Go to
Guide
PLC jumper on Veichi: wiring PNP/NPN sensors and pushbuttons
On the control board of Veichi AC10 (from 7.5 kW) and AC310 three terminals sit side by side: +24V, PLC and COM. Between them is a small jumper. Its p...
Go to
Guide
VFD grounding and stray voltage on the enclosure (PE, >5V)
A fairly common complaint after installation: voltage "tingles" on the motor housing, the cabinet or the drive itself, while the keypad or sensors sta...
Go to
Guide
Shielding a 4-20mA sensor: which end to ground, 15 cm separation
A pressure or flow sensor in pump automation almost always outputs a 4-20 mA current signal. On Veichi it is wired to an analog input that can operate...
Go to
Guide
Replacing a Schneider Altivar with Veichi: step-by-step terminal and parameter migration
The power section of a Schneider Altivar and a Veichi is wired the same way: mains to R/S/T, motor to U/V/W, PE to the ground terminal. The difficulty...
Go to
SIMILAR AL2-14MR-D GOODS
| Characteristics | |||||
|---|---|---|---|---|---|
| brand | Schneider Electric | Siemens | Siemens | Siemens | Siemens |
| Series | SR2 | S7-1200 | S7-1200 | S7-1200 | S7-1200 |
| module type | PLC | PLC | PLC | PLC | PLC |
| supply_voltage | - | - | - | - | - |
| output_type | - | - | - | - | - |
| Interface | No | ||||
| Number of inputs | 6 | ||||
| Relay outputs | - | - | - | - | - |
| USB port | - | - | - | - | - |
| Number of digital outputs | 4 | 4 | 4 | 4 | 6 |
| high_speed_outputs | - | - | - | - | - |
This page contains information about
Alpha XL PLC base module for DC 24 V supply; 8 inputs DC 24 V; 6 relay outputs ( AL2-14MR-D )
with a detailed description of the technical characteristics
.
You can download
documentation for AL2-14MR-D, series Alpha 2 from manufacturer Mitsubishi Electric
.
Buy AL214MRD
and seek technical advice.
Our Engineers will help you choose and buy
AL2-14MR-D only high quality at affordable prices. Guarantee.
AL2-14MR-D