Skip to content

FBs-CBE Fatek FBs-CBE — Ethernet 10 Base T communication board

Є в наявності
sku: FBs-CBE
FBs-CBE Fatek FBs-CBE — Ethernet 10 Base T communication board
Клікніть для збільшення
Fatek
Є в наявності
4 787 UAH
brand: Fatek
Series: FBs-Communication
module type: COM
supply_voltage:
output_type:
Interface: Ethernet 10BaseT
Number of inputs:
Relay outputs:
USB port: No
Number of digital outputs:
high_speed_outputs:

delivery-iconDelivery and payment methods

  • Nova Poshta OfficeBy Nova Poshta to a branch or courier to the address
  • OplataBank transfer payment

delivery-iconService and Warranty

  • 24-month Warranty
  • Product return within 14 days
  • Official Service Center

delivery-iconTechnical support

  • Help with setup and selection
  • Зацікавив товар?
    Наш продавець проконсультує Вас.
  • Characteristics
  • Documentation
  • Reviews (0)
brand Fatek
Series FBs-Communication
module type COM
sku FBs-CBE
Number of ports 1
Interface Ethernet 10BaseT
USB port No
Note Комунікаційна плата Ethernet 10 Base T; 9.6 K – 230.2 Kbps.
Accession No
Documents by language

Ukrainian / English / Russian

Chastotnik.ua

Practical setup guides

Chastotnik.ua materials for wiring and setup. These are not official manufacturer documents.

Guide Replacing a European VFD with Veichi: NPN/PNP, PLC jumper, COM vs GND The most common scenario when replacing a European drive (Schneider Altivar, Siemens, LS, Danfoss) with Veichi looks like this: the power section is w... Go to Guide COM or GND: why the buttons do not work on a Veichi VFD A typical picture after installation: the Veichi VFD starts from the keypad, the parameters are entered, but the external Start/Stop buttons produce n... Go to Guide PLC jumper on Veichi: wiring PNP/NPN sensors and pushbuttons On the control board of Veichi AC10 (from 7.5 kW) and AC310 three terminals sit side by side: +24V, PLC and COM. Between them is a small jumper. Its p... Go to Guide VFD grounding and stray voltage on the enclosure (PE, >5V) A fairly common complaint after installation: voltage "tingles" on the motor housing, the cabinet or the drive itself, while the keypad or sensors sta... Go to Guide Shielding a 4-20mA sensor: which end to ground, 15 cm separation A pressure or flow sensor in pump automation almost always outputs a 4-20 mA current signal. On Veichi it is wired to an analog input that can operate... Go to Guide Replacing a Schneider Altivar with Veichi: step-by-step terminal and parameter migration The power section of a Schneider Altivar and a Veichi is wired the same way: mains to R/S/T, motor to U/V/W, PE to the ground terminal. The difficulty... Go to
Product Reviews

No reviews yet. Be the first!

SIMILAR FBs-CBE GOODS

Characteristics
brandDelta ElectronicsSchneider ElectricSiemensSiemensDelta Electronics
SeriesASSR3S7-1200S7-1200AS
module typeCOMCOMCOMCOMCOM
supply_voltage-----
output_type-----
InterfaceRS232RS485RS232RS485RS232
Number of inputsNoNoNo
Relay outputs-----
USB port-----
Number of digital outputs-----
high_speed_outputs-----
This page contains information about Fatek FBs-CBE — Ethernet 10 Base T communication board ( FBs-CBE ) with a detailed description of the technical characteristics . You can download documentation for FBs-CBE, series FBs-Communication from manufacturer Fatek . Buy FBsCBE and seek technical advice. Our Engineers will help you choose and buy FBs-CBE only high quality at affordable prices. Guarantee. FBs-CBE