AuCom EMX4e soft starter: display and bypass, 7.5-280 kW

The EMX4e is AuCom's mid range, with a full display. Current runs 24 to 580 A, power 7.5-280 kW at 400 V, and we stock 17 positions. Supply is 200-525 V, wider than the CSX, which helps on sites where the incoming voltage is not exactly what the drawings promised. The bypass is built into the whole series. So the cabinet barely warms up after acceleration, and no extra fan is needed in the panel.

We pick the EMX4e when the CSXi runs out of current but the top EMX4i would be overkill. The display is not decoration. commissioning goes faster because parameters are visible, with no counting of switch positions. Typical duties are pumping stations, ventilation plant and mid-power conveyors, which is exactly the segment where the CSXi hits its current ceiling but paying for the flagship buys nothing useful. If you need adaptive start control or SCADA communication, look at the EMX4i. A cheaper option without a display is the CSXi.

What we ask before quoting

Nameplate current, load type, starts per hour, cabinet temperature. A centrifugal pump and a loaded conveyor need different sizing even at identical kilowatts, because breakaway torque differs by a wide margin. Above 40 °C in the enclosure derating applies. A line breaker and line contactor are needed regardless of series.

Prices and documentation

The EMX4e opens at UAH 27,525, and the top EMX4e-0580B-V5-C1-H at 580 A costs UAH 205,070. We send the series manual with the invoice, before payment. The full brand line sits under AuCom, with everything else in the soft starter catalogue.

Frequently Asked Questions

What is the difference between EMX4e and EMX4i?

Current and control level. The EMX4e covers 24-580 A with a display and fast commissioning. The EMX4i reaches 1000 A and adds adaptive start control, extended diagnostics plus communication. At the same 200 A the prices are UAH 79,760 against UAH 97,270. Take the EMX4i when the start is hard, or when the unit must report into SCADA.

What power does the EMX4e handle?

From 7.5 to 280 kW at 400 V, current 24-580 A, across 17 positions. We size by nameplate current. A loaded conveyor takes a larger frame than a centrifugal pump of the same rating, because breakaway torque differs by a wide margin.

What supply voltage does the EMX4e accept?

200-525 V. That is wider than the CSX and CSXi with their 440 V ceiling. Ukrainian 380 V is covered with margin, and 400 or 480 V networks work without modification.

Is an external bypass required?

No, the bypass is built into the entire EMX4e series. After acceleration the panel barely warms. A line breaker and a line contactor for emergency disconnect are needed regardless.

How much does an AuCom EMX4e cost?

From UAH 27,525 in the smallest frame to UAH 205,070 for the EMX4e-0580B-V5-C1-H at 580 A. Please confirm availability of a specific position with a manager.

Where do I get the EMX4e manual?

We send the series manual with the invoice, before payment. If you need parameters for your machine, tell us the load type plus motor current, and we will send starting values for ramp time and initial voltage.