EURA Frequency Inverters

Found 45 products
EURA ×
Скинути фільтри

EURA Frequency Inverters

EURA Drives builds drive equipment in China and runs a European arm, EURA Drives Europe. The manufacturer states its products ship to 46 countries. We carry three series: E810 as the workhorse, E2100 for vector duty and the compact E600. The older E800 and E2000 are out of production, so we do not stock them. E810 and E2100 drop into the same mounting.

E810: the everyday line

This is the E800 successor. Same mounting, same part-number logic, so the swap is one for one. Three control modes: scalar VVVF, sensorless vector SVC, and SVC for permanent-magnet synchronous motors. Starting torque is 150 % at 0.5 Hz, speed range 1:100, output frequency 0.5–650 Hz.

Overload here is 120 % for 60 s. That figure comes from the official manual and it is the first one to check: the series is not built for shock loads, while a pump, fan or conveyor runs on it comfortably. Enclosure is IP20 and the ambient range is −10 to +40 °C, so it belongs inside a cabinet.

On board you get a built-in PID, 15 preset speeds, two analogue inputs and Modbus RTU over RS485 (terminals A+/B−). The EMC filter and the braking unit are options on E810, ordered through the part number.

E2100: when E810 runs out of headroom

The E2000 successor and a step up in control. Overload is 150 % for 60 s. Vector control with an encoder is available through an expansion card, not just sensorless operation. Beyond the base Modbus, fieldbuses are added by option code: CANopen, EtherCAT, Profibus-DP, BACnet.

Safe torque off is available, but as an option: certification code U8 (CE plus STO), offered up to 180 kW. The official manual does not state a SIL level, so neither do we.

A class C3 EMC filter is standard up to 45 kW: code R5 is rated for roughly 10 m of shielded motor cable, R3 for 25 m. From 55 kW the filter is a separate item. The braking chopper is standard on three-phase 400 V units up to 30 kW, and from 132 kW only an external module will do.

Our catalogue holds the core of the series: three-phase 400 V from 0.75 to 30 kW. The rest of the range is brought in to order, since the manual takes the series much higher.

E600: compact, for a small cabinet

0.2–5.5 kW, two frame sizes Q1 and Q2, fed from single-phase 220–240 V or three-phase 400 V. Cooling is natural up to 0.4 kW and forced above that. We reach for it when the job is simply turning a fan or a small pump and cabinet space is tight.

Reading the part number

The power code is kW multiplied by 10. E810-0007S2 is 0.75 kW, E2100-0300T3 is 30 kW. The letters that follow give the supply: S2 single-phase 220–240 V, T2 three-phase 230 V, T3 three-phase 380–480 V. The same logic runs through all three series, so it is hard to get wrong. The tail of the code covers the filter, braking chopper, fieldbus, certification and keypad; we list the short form and agree the rest at order time.

What we ask before ordering

The motor rated current from the nameplate, not the kW. The load type: a pump or fan means E810, while shock torque or an encoder requirement means E2100. The supply voltage: single-phase 220 V or three-phase 380 V. Stock and price are shown on each model card, and we answer on request for the remaining part numbers.

Related sections: all frequency inverters, VFDs for pumps, VFDs for fans, vector control VFDs, VFDs for single-phase pumps. EURA series: E810, E2100, E600. Comparable alternatives: INVT, Veichi, Frecon.

Frequently Asked Questions

How does E810 differ from E800?

E800 is out of production and E810 is its direct successor. The mounting and the part-number logic match, so an E810-0011S2 goes where an E800-0011S2 was without reworking the cabinet. The series also replaces the older E1000. We do not stock new E800 units precisely because the maker closed that line.

What do the digits in E810-0007S2 mean?

0007 is the power code, kW multiplied by 10, so 0.75 kW. S2 means a single-phase 220–240 V supply, T2 three-phase 230 V, T3 three-phase 380–480 V. The same logic applies to E810, E2100 and E600. The rest of the code covers the EMC filter, braking chopper, fieldbus, certification and keypad, and is configured at order time.

How does E2100 differ from E810?

Three things. Overload of 150 % for 60 s against 120 % on E810. Vector control with an encoder through an expansion card, not only sensorless. Optional CANopen, EtherCAT, Profibus-DP and BACnet on top of the base Modbus. If the job is a pump or a fan you will not use any of it, and E810 costs less.

Does EURA offer safe torque off (STO)?

E2100 does, as an option: certification code U8, meaning CE plus STO, offered up to 180 kW. The official manual states no SIL level, so neither do we. E810 and E600 have no STO at all. If the project needs STO, say so before ordering, because the code is part of the part number.

What communication interface is on board?

E810 has Modbus RTU over RS485 on terminals A+/B−, with nothing to add. On E2100 Modbus is also standard (code F2), while CANopen, EtherCAT, Profibus-DP and BACnet are ordered under a separate code. The bus is chosen at order time: it is built into the part number rather than fitted as a card afterwards.

Can it run from a single-phase 220 V supply?

Yes, the S2 versions are fed from single-phase 220–240 V. On E810 that covers 0.2 to 2.2 kW, and E600 also goes up to 2.2 kW. The motor is still three-phase: the inverter builds the three phases itself. If you need to drive a genuinely single-phase capacitor pump, see the separate section on VFDs for single-phase pumps.

Is an external EMC filter needed?

It depends on the series and the rating. On E2100 a class C3 filter is built in up to 45 kW: code R5 is rated for roughly 10 m of shielded motor cable, R3 for 25 m. From 55 kW the filter becomes a separate item. On E810 the EMC filter is an option and is not fitted in the base version.

Is a braking resistor required?

If the machine carries inertia and has to stop quickly, yes. On E2100 the braking chopper is standard for three-phase 400 V units up to 30 kW, built to special order between 37 and 110 kW, and from 132 kW only an external braking module works. On E810 the braking unit is an option. We size the resistor itself against the inertia and the braking cycle, so send us the machine data.

What enclosure rating and ambient temperature?

E810 is IP20 with an ambient range of −10 to +40 °C, so it mounts inside a cabinet. E600 is a cabinet unit as well. We currently carry no high-IP outdoor EURA versions, so for outdoor, wash-down or dusty sites look at the other brands in the general frequency inverter section.

Where can I get the series manual?

Official manuals exist for E810 and E2100, and we send them on request together with the frame-size table and the wiring diagram. For E600 the maker publishes no full manual: there is a series page with the Q1 and Q2 frame dimensions and currents. Tell us the exact part number and we will reply with the document.