DVP04DA-SL Analog output module 04 I/O points left side bus
Є в наявності
sku: DVP04DA-SL
Є в наявності
Ціна за запитом
brand: Delta Electronics
Series: DVP-SV
module type: MOD
supply_voltage:
output_type:
Interface: No
Number of inputs: No
Relay outputs:
USB port:
Number of digital outputs:
high_speed_outputs:
Delivery and payment methods
By Nova Poshta to a branch or courier to the address
Bank transfer payment
Service and Warranty
- 24-month Warranty
- Product return within 14 days
- Official Service Center
Technical support
- Help with setup and selection
- Зацікавив товар?
Наш продавець проконсультує Вас.
- Characteristics
- Documentation
- Reviews (1)
| brand | Delta Electronics |
| Series | DVP-SV |
| module type | MOD |
| sku | DVP04DA-SL |
| supply_voltage_V | 24DC |
| Number of inputs | No |
| Number of digital inputs | No |
| Input voltage | No |
| Type of discrete input signals | No |
| Number of analog inputs | No |
| Type of analog inputs | No |
| Number of high frequency inputs | No |
| Input frequency | нет kHz |
| Number of outputs | 4 |
| Type of digital outputs | No |
| Number of analog outputs | 4 |
| Type of analog outputs | 0-20mA #0-10V |
| Maximum voltage/current output common per point | No |
| Number of ports | No |
| Interface | No |
Documents by language
Ukrainian / English / Russian
EN English
Chastotnik.ua
Practical setup guides
Chastotnik.ua materials for wiring and setup. These are not official manufacturer documents.
Guide
Replacing a European VFD with Veichi: NPN/PNP, PLC jumper, COM vs GND
The most common scenario when replacing a European drive (Schneider Altivar, Siemens, LS, Danfoss) with Veichi looks like this: the power section is w...
Go to
Guide
COM or GND: why the buttons do not work on a Veichi VFD
A typical picture after installation: the Veichi VFD starts from the keypad, the parameters are entered, but the external Start/Stop buttons produce n...
Go to
Guide
PLC jumper on Veichi: wiring PNP/NPN sensors and pushbuttons
On the control board of Veichi AC10 (from 7.5 kW) and AC310 three terminals sit side by side: +24V, PLC and COM. Between them is a small jumper. Its p...
Go to
Guide
VFD grounding and stray voltage on the enclosure (PE, >5V)
A fairly common complaint after installation: voltage "tingles" on the motor housing, the cabinet or the drive itself, while the keypad or sensors sta...
Go to
Guide
Shielding a 4-20mA sensor: which end to ground, 15 cm separation
A pressure or flow sensor in pump automation almost always outputs a 4-20 mA current signal. On Veichi it is wired to an analog input that can operate...
Go to
Guide
Replacing a Schneider Altivar with Veichi: step-by-step terminal and parameter migration
The power section of a Schneider Altivar and a Veichi is wired the same way: mains to R/S/T, motor to U/V/W, PE to the ground terminal. The difficulty...
Go to
Product Reviews
1
Overall rating
5.0
out of 5
1 reviews
5
1
4
0
3
0
2
0
1
0
�
Олексій В.
Взяв модуль DVP04DA-SL для одного проекту, треба було додати 4 аналогових виходи. Став на шину DVP без проблем, живлення 24В DC стандартне. Видає як 0-20мА, так і 0-10В, що дуже зручно для підключення різних виконавчих механізмів. Delta як завжди не підводить по співвідношенню ціна/можливості) Працює стабільно.
To leave a review, please, log in.
This page contains information about
Analog output module 04 I/O points left side bus ( DVP04DA-SL )
with a detailed description of the technical characteristics
.
You can download
documentation for DVP04DA-SL, series SV from manufacturer Delta Electronics
.
Buy DVP04DASL
and seek technical advice.
Our Engineers will help you choose and buy
DVP04DA-SL only high quality at affordable prices. Guarantee.
DVP04DA-SL