Frequency converters 200.0 kW

Found 81 product
200 ×
Скинути фільтри
B2B Сервіс

200 kW Variable Frequency Drive — Selection and Applications

200 kW variable frequency drives (VFDs) provide precise speed and torque control for large industrial AC motors. Input supply: 3x380 V, output current: 377–385 A. Full catalog: variable frequency drives (VFD).

Applications for 200 kW VFDs

This power class is used wherever large electric motors require smooth speed regulation:

  • Pumping stations — main water supply and sewage pumps, cooling pumps for industrial systems.
  • Ventilation and HVAC — large axial and centrifugal fans in mines, production halls, and cold storage facilities.
  • Compressors — screw and centrifugal compressors for compressed air and industrial gases.
  • Conveyor systems and crushers — belt conveyors in quarries, mine hoists, stone crushers, mills.
  • Metallurgy and shipbuilding — winches, crane mechanisms, mixers, hydraulic press pumps.

200 kW Variable Frequency Drive Models

Below are 200 kW models available in stock or on order. All rated for 3x380 V, 50 Hz supply.

Model Brand / Series Output current, A IP Key feature
ACQ80-01-200KW-4 ABB ACQ80 385 IP21 Dedicated pump/fan drive, built-in PID controller, dry-run protection
ACQ80-07-200KW-4 ABB ACQ80 385 IP21 Built-in DC choke version, reduced harmonic distortion, water supply applications
AC310-T3-200G/220P-L Veichi AC310 380 IP20 Vector control, built-in PLC, G/P mode (200 kW heavy / 220 kW fan/pump load)
AC70-T3-200G/220P Veichi AC70 380 IP20 Closed-loop vector control, 150% overload for 60 s, high torque accuracy
GD200A-200G/220P-4 INVT GD200A 380 IP20 SVC/FVC vector control, built-in PLC and PID, G/P configuration
DX100-4T2000Q Simphoenix DX100 385 IP20 FOC vector control, f_max 1000 Hz, suitable for spindle and high-speed drives
p0800122 ENEXT e.f-drive.pro 377 IP20 Ukrainian manufacture, SVC control, f_max 300 Hz, built-in EMC filter

How to Choose a 200 kW VFD

Key parameters for correct selection:

  • Load type — for pumps and fans (quadratic torque) use G/P models in P mode (220 kW); for heavy loads (conveyors, crushers) use G mode (200 kW, 150% overload for 60 s).
  • Protection class — for dusty or wet environments, prefer IP21 (ABB ACQ80) or IP20 cabinet-mounted with additional enclosure.
  • Control method — for precise speed and torque control, select a drive with FOC or closed-loop vector control (Simphoenix DX100, Veichi AC70).
  • Communication interface — for SCADA or Modbus/PROFIBUS integration, confirm the required communication option.

Other VFD power ratings

If 200 kW does not match your requirements, browse adjacent power ratings: 160 kW, 185 kW, 220 kW, 250 kW, 315 kW.

Warranty and support

All variable frequency drives carry official manufacturer warranty. Delivery across Ukraine via Nova Poshta and courier services. Payment by bank transfer, VAT invoice for legal entities. Technical selection support available by phone and email — see the VFD catalog page.

Frequently Asked Questions

What is a variable frequency drive and how does it work?

A VFD is an electronic device that converts AC mains voltage to DC (rectifier stage), then back to AC with adjustable frequency and amplitude (inverter stage). By varying the output frequency from 0 to 600 Hz, it smoothly controls the rotational speed of an AC induction motor from standstill to rated speed and beyond, while limiting starting current to 1.5× rated.

How do I size a VFD for my motor?

The VFD power rating should equal or exceed the motor nameplate power. For pumps and fans (variable torque), select based on the motor rating. For conveyors, cranes, and crushers (constant torque or heavy starting), choose one power step above — for example, for a 4 kW conveyor motor, we recommend a 5.5 kW VFD. Also verify that the motor's rated current does not exceed the VFD's current rating.

Can I run a three-phase 380V motor from a single-phase 220V supply?

Yes, you need a VFD with single-phase 220V input and three-phase 380V output, such as the Veichi AC70E or AC10 T/S2 variant. Power is limited to 2.2–4 kW depending on the series. The VFD not only starts the motor but also provides soft starting, speed control, and overload protection.

What is the difference between scalar and vector control?

Scalar control (V/f) maintains a constant voltage-to-frequency ratio — a simple, reliable method for pumps, fans, and compressors. Vector control (SVC, FOC) calculates motor current and flux vectors in real time, delivering 150–200% rated torque at low frequencies. Vector control is essential for conveyors, elevators, extruders, cranes, and CNC machine tools.

Why do I need an EMC filter in a VFD?

An EMC (electromagnetic compatibility) filter reduces high-frequency interference that the VFD generates in the power supply and airwaves. It is mandatory for facilities with sensitive equipment (medical, laboratories, server rooms), residential buildings, and when the cable between VFD and motor exceeds 25 m. The Veichi AC10, Delta VFD-E, and INVT GD20 models include a built-in Class C3 EMC filter.

How much energy does a VFD save?

On pumps and fans, savings range from 20% to 60% depending on the load profile. Power is proportional to the cube of speed (P∝n³): reducing speed by 20% halves energy consumption. If equipment typically operates at 70–80% of rated speed, average savings are approximately 40%. Payback period for a VFD on a pumping station is 6 to 18 months.