Skip to content

131B0064 Variable Frequency Drive VLT FC302 0.55kW 3ph/380

sku: 131B0064
131B0064 Variable Frequency Drive VLT FC302 0.55kW 3ph/380
Клікніть для збільшення
Danfoss
see_alternalive_items
Ми зрадістю підбермо Вам аналог Професійний підбір за тел. (093) 1701425
brand: Danfoss
Series: VLT FC302
Supply input: 3x380 V
Сurrent: 2.4 A
IP protection level: 20
Hybrid Power (AC/DC-Solar): Ні
Remote Control: Ні

delivery-iconDelivery and payment methods

  • Nova Poshta OfficeBy Nova Poshta to a branch or courier to the address
  • OplataBank transfer payment

delivery-iconService and Warranty

  • 24-month Warranty
  • Product return within 14 days
  • Official Service Center

delivery-iconTechnical support

  • Help with setup and selection
  • Зацікавив товар?
    Наш продавець проконсультує Вас.
  • Characteristics
  • Description
  • Documentation
  • Reviews (0)
brand Danfoss
Series VLT FC302
sku 131B0064
Main Power 0.5 kW
Supply input 3x380 V
Supply output 3x380 V
Сurrent 2.4 A
IP protection level IP20
EMC filter Available
Scalar control mode Available
Vector control mode without encoder Available
Linear U/f control law Available
Quadratic control law U/f2 Available
Hybrid Power (AC/DC-Solar) Ні
Remote Control Ні
Documents by language

Ukrainian / English / Russian

Chastotnik.ua

Practical setup guides

Chastotnik.ua materials for wiring and setup. These are not official manufacturer documents.

Guide Replacing a European VFD with Veichi: NPN/PNP, PLC jumper, COM vs GND The most common scenario when replacing a European drive (Schneider Altivar, Siemens, LS, Danfoss) with Veichi looks like this: the power section is w... Go to Guide COM or GND: why the buttons do not work on a Veichi VFD A typical picture after installation: the Veichi VFD starts from the keypad, the parameters are entered, but the external Start/Stop buttons produce n... Go to Guide PLC jumper on Veichi: wiring PNP/NPN sensors and pushbuttons On the control board of Veichi AC10 (from 7.5 kW) and AC310 three terminals sit side by side: +24V, PLC and COM. Between them is a small jumper. Its p... Go to Guide VFD grounding and stray voltage on the enclosure (PE, >5V) A fairly common complaint after installation: voltage "tingles" on the motor housing, the cabinet or the drive itself, while the keypad or sensors sta... Go to Guide Shielding a 4-20mA sensor: which end to ground, 15 cm separation A pressure or flow sensor in pump automation almost always outputs a 4-20 mA current signal. On Veichi it is wired to an analog input that can operate... Go to Guide Replacing a Schneider Altivar with Veichi: step-by-step terminal and parameter migration The power section of a Schneider Altivar and a Veichi is wired the same way: mains to R/S/T, motor to U/V/W, PE to the ground terminal. The difficulty... Go to
Product Reviews

No reviews yet. Be the first!

SIMILAR 131B0064 GOODS

Characteristics
brandVeichiSchneider ElectricINVTDelta ElectronicsMitsubishi Electric
SeriesAC10Altivar 320GD10VFD-ELFR-D
Supply input, V3x3803x3803x3803x3803x380
Сurrent, A31.92.52.52.2
IP protection level2020202020
Hybrid Power (AC/DC-Solar)NoNoNoNoNo
Remote ControlNoYesNoNoNo
This page contains information about Variable Frequency Drive VLT FC302 0.55kW 3ph/380 ( 131B0064 ) with a detailed description of the technical characteristics . You can download documentation for 131B0064, series VLT FC302 from manufacturer Danfoss . Buy 131B0064 and seek technical advice. Our Engineers will help you choose and buy 131B0064 only high quality at affordable prices. Guarantee. 131B0064